TM 9-2320-387-10
2-50.1. TROOP/CARGO WINTERIZATION HEATER
OPERATING INSTRUCTIONS
a. General.
Troop/cargo winterization heater is for use during extremely cold
temperatures from 0F (-18C) to -50F (-46C).
CAUTION
Do not operate troop/cargo heater in ambient temperatures above
0F (-18C), or with fan switch in HI position, when temperature is
above -25F (-32C). Damage to equipment will result.
NOTE
Heater may be operated with engine running or engine off.
b. Starting Heater.
(1) Set heater fan switch (3) to LO position.
(2) Move heater control switch (2) to START position and hold for
approximately two minutes or until heater starts and heater indicator light (1)
comes on.
(3) When heater starts, move heater control switch (2) to RUN position.
The heater indicator light (1) will remain illuminated.
(4) Set heater fan switch (3) to desired position (HI or LO).
c. If Heater Fails to Start:
NOTE
If the start switch is moved from the START to RUN position too
quickly, the heater flame will be extinguished and the heater will
need restarting.
(1) Move heater control switch (2) to OFF position for 10 seconds, and then
back to START for 60 seconds. Repeat procedure if heater doesn't start.
NOTE
If heater indicator light works and heater still fails to start in
approximately three minutes, service is required
(2) Press heater indicator light (1) to test electrical circuit.
d. Shutting Heater Off.
Move heater control switch (2) to OFF.
NOTE
The heater indicator light will remain on and the fan will continue
to run until the heater has purged itself of fuel.