TM 9-2330-227-14&P
WALL RECEPTACLE CABLES - CONTINUED
ACTION
REMARKS
ITEM
LOCATION
INSTALLATION
NOTE
Steps 25 thru 36 apply to right or left side wall receptacle cables.
a. From bulk cable, cut new cables
New cables
25.
to same length as old cables.
(1) and (2)
b. Strip insulation back 3/4-inch (19 mm)
from each end using wire strippers.
NOTE
If end of cable is connected to shiny silver contact screw to start with, that cable should
be connected to silvery screw at each receptacle. The same applies to the cable
connected to bronze finish contact screw.
Wrap bare wire around screw.
Cable (1)
Contact screw (3)
26.
at receptacle (4)
Tighten using 3/16-inch flat-tip
Screw (3)
27.
Cable (1)
screwdriver.
a.
Strip 3/4-inch (19 mm) insulation
Cable (1)
Contact screw (5)
28.
from cable (1) at a point 2-ft
at receptacle (6)
(50.8 mm) from contact screw (3).
b. Wrap bare wire around screw.
Tighten using 3/16-inch flat-tip
Screw (5)
Cable (1)
29.
screwdriver.
Repeat steps 26 thru 29 until cable
Wrap bare wire around screw.
Cable (2)
Contact screw (7)
30.
at receptacle (4)
Tighten using 3/16-inch flat-tip
Screw (7)
Cable (2)
31.
screwdriver.
a. Strip 3/4-inch (19 mm) insulation
Cable (2)
Contact screw (8)
32.
from cable (2) at a point 2-ft
at receptacle (6)
(50.8 mm) from contact screw (7).
b. Wrap bare wire around screw.
5-28