TM 9-2330-235-14&P
4-35.
AIR FILTER REPAIR.
This Task Covers:
a. Disassembly
c. Assembly
b. Cleaning and Inspection
Initial Setup.
Equipment Conditions:
Materials/Parts:
Dry clearing solvents (Item 13, Appendix E)
Antiseizing tape (Item 15, Appendix E)
Tools/Test Equipment:
General mechanic's tool kit
One filter element
One gasket
a.
DISASSEMBLY
1. Remove plug (7) from adapter bushing (6).
2. Remove adapter bushing (6) and gasket (5) from
elbow body (1) Discard gasket
3. Remove spring (4), spring tension washer (3),
and filter element (2) from elbow body (1).
Discard filter element
b.
CLEANING AND INSPECTION
WARNING
Dry cleaning solvent, P-D-680, is toxic and flammable. Always wear protective goggles and
gloves, and use only in a well-ventilated area. Avoid contact with skin, eyes, and clothes, and DO
NOT breathe vapors. DO NOT use near open flame or excessive heat. The solvent's flash point is
100'F-138'F (38'C-59'C). If you become dizzy while using cleaning solvent, immediately get fresh
air and medical help. If solvent contacts eyes, immediately wash your eyes and get medical aid.
1. Clean ail parts with dry cleaning solvent and dry thoroughly
2. Inspect al' part for cracks, breaks, corrosion, or other damage Replace if damaged
TA505032
4-80