TM 9-2330-297-14&P
RELAY VALVE - SERVICE AND EMERGENCY - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
5.
Air
Relay valve (1)
Using pipe wrench and sealing compound on
reservoir (7)
and nipple (6)
threads of nipple (6), install nipple (6)
and relay valve (1) in air reservoir (7).
6.
Relay valve (1)
Airhoses (4)
Using 7/8-inch wrench and sealing com-
and (5)
pound on threads of hose end fittings,
install hoses (4) and (5).
7.
Air lines (2)
Using 5/8-inch wrench and sealing com-
and (3)
pound, install lines (2) and (3)
NOTE
FOLLOW-ON MAINTENANCE:
1.
Close air reservoir draincock
2.
Charge air system and check for leaks
TASK ENDS HERE
TA223148
4-65