TM 9-2330-357-14&P
5-2. MASTER RELAY WIRING HARNESS REPLACEMENT (Con't).
4. Remove bolt (3), lockwasher (2), and ground connector (1) from frame. Discard lockwasher.
5. Remove four screws (11), lockwashers (9), and nuts (8). Discard lockwashers.
6. Slide connector (10) and master relay wiring harness (6) out of frame.
b. INSTALLATION
1. Install connector (10) and master relay wiring harness (6) into frame with four nuts (8), new lockwashers (9),
and screws (11).
2. Install ground connector (1) to frame with new lockwasher (2) and bolt (3).
3. Connect connector (7) to main wiring harness.
4. Connect connector (5) to circuit breaker box.
5. Connect connector (4) to master relay box.
FOLLOW-ON TASKS:
5-9