TM 9-2330-371-14&P
AIR LINES AND FITTINGS (EMERGENCY RELAY VALVE TO AIR CHAMBERS
AND RESERVOIR) - CONTINUED
ACTION
REMARKS
ITEM
LOCATION
INSTALLATION CONTINUED
Put through.
Hose (2)
Grommet hole (1)
16.
Push into hole.
Grommet (3)
17.
a. Wrap both threads two turns counter-
Nipple (5)
18.
clockwise with teflon tape.
b. Put in and tighten using 9/16-inch
wrench.
Put on and tighten using 5/8-inch wrench.
Hose (2) and
19.
If installing hose and fittings from
fitting (6)
and nipple (5)
rear air chamber to relay valve
only, go to follow-on maintenance.
a. Wrap both threads two turns counter-
Elbow (7)
20.
clockwise with teflon tape.
b. Put in and tighten using 5/8-inch
wrench.
Put on and tighten using 5/8-inch
Hose (8) and
21
wrench.
fitting (9)
and elbow (7)
a. Wrap both threads two turns counter-
Elbow(n)
Air chamber (10)
22.
clockwise with teflon tape.
b. Put in and tighten using 5/8-inch
wrench.
TA224274
4-96