TM 9-2330-373-14 & P
4-27.
AIR HALF-COUPLING
THIS TASK COVERS
a.
Removal
b.
Cleaning
c.
Inspection and replacement
d.
Installation of packing ring
e.
Installation
Test Equipment Required:
None
Personnel Required:
1
REMOVAL
1. Hold adapter (1) stationary with a wrench and
unscrew half-coupling (2).
2. Pry packing ring (3) from body. Discard packing
ring.
CLEANING
1. Clean mud and dirt from all exposed surfaces with water and a stiff brush.
WARNING
Cleaning solvent, used to clean parts, is potentially dangerous to
personnel and property. Do not use near open flame or excessive
heat. Flash point of solvent is 138F (58.8C).
2. Remove grease with cleaning solvent (item 3, appendix E)
TA 314792
4-72