TM 9-2330-373-14 & P
Section III. MAINTENANCE PROCEDURES
5-5. WIRING HARNESS CONNECTOR AND RECEPTACLE
MALE TYPE PLUG ASSEMBLY (WITH SPANNER COUPLING NUT
4
- PASS REPLACEMENT CABLE THROUGH GROMMET
1
- STRIP CABLE INSULATION EOUAL TO DEPTH OF
RETAINING NUT AND GROMMET INSERT INTO
SOLDER WELLS OF INSERTS
AND SOLDER.
2
- REMOVE GROMMET RETAINING NUT FROM PLUG
5
- SLIDE GROMMET OVER INSERTS AND PRESS INTO
ASSEMBLY AND REMOVE DAMAGED CABLE.
PLUG ASSEMBLY UNTIL SEATED
3
- SLIDE GROMMET BACK FROM PLUG ASSEMBLY
6
-THREAD GROMMET RETAINING NUT TO PLUG .
AND REMOVE DAMAGED CABLE.
4
- PASS REPLACEMENT CABLE ENDS THROUGH
1
- STRIP CABLE INSULATION EQUAL TO DEPTH OF
GROMMET RETAINING NUT AND GROMMET. INSERT
INTO SOLDER WELLS OF INSERTS,ANDSOLDER.
2
- REMOVE GROMMET RETAINING NUT FROM PLUG
5
- SLIDE GROMMET OVER INSERTS AND PRESS INTO
ASSEMBLY AND SLIDE BACK OVER CABLE.
RECEPTACLE ASSEMULY UNTIL SEATED.
3
- SLIDE GROMMET BACK FROM
6
- THREAD GROMMET RETAINING NUT TO RECEPTACLE
ASSEMBLY AND REMOVE DAMAGED CABLE .
ASSEMBLY.
* NOTE: CONTACT SIZES 8, 4 AND 0 MAY BE REMOVED FROM CONNECTOR TO SIMPLIFY REPAIR
5-6. WIRING HARNESS
THIS TASK COVERS
a. Removal
b. Installation.
c. Replacement of single wires
Test Equipment Required:
Personnel Required:
1
TA 314853
5-3