TM 9-2330-381-14
3-3.
LUBRICATION CHART
The lubrication chart provides instructions for lubrication procedures, use of proper materials for lubing, and
recommended time between lubing. Location of fittings and other points to be serviced are included.
LUBRICATION CHART
SEMITRAILER, TRANSPORTER, HEAVY EQUIPMENT
70 TON, M1000
Intervals are based on normal operation (on-condition or hard time). Change the hard time interval if you are operating
the equipment under adverse operating conditions including longer-than-usual operating hours. The hard time interval
may be extended during periods of low activity. If extended, adequate preservation precautions must be taken.
WARNING
Dry cleaning solvent (P-D-680, Type III) is used to clean parts and is potentially
dangerous to personnel and property. Extinguish all smoking materials and do not
allow sparks or open flame near the work area. Use skin and eye protection and
work in a well-ventilated area. Flash point of dry cleaning solvent is 200F (93C).
Clean fittings before lubricating. Clean parts with dry cleaning solvent. Dry before lubricating.
Level of Maintenance. The lowest level of maintenance authorized to lubricate a point is indicated by one of the following
symbols as appropriate: Operator/crew (C); and Unit Maintenance (O).
WARNING
Before performing lubrication procedures on semitrailer, raise platform to highest
isolation valves or injury to personnel may result.
NOTE
Where "Daily" services are specified, daily shall be interpreted to mean only on
days when equipment is operated.
3-2 Change 1