TM 9-2330-381-14
4-79.
SUSPENSION CONTROL MANIFOLD (CONT)
REPAIR
Replace all parts found defective and replace all preformed packings and backup rings using respective repair kits.
ASSEMBLY
CAUTION
As the flow regulating and cartridge valves are assembled, the arrangement of
preformed packings and backup rings is extremely important. If the preformed
packing and backup rings are improperly installed, internal leakage or premature
equipment failure may result. Use the illustration shown for proper arrangement of
parts.
1.
Apply petroleum Jelly to preformed packings (17 and 20) and backup rings (18 and 19).
2.
Remove caps/plugs and install preformed packing (20), backup rings (18 and 19), and preformed packing (17)
onto FCCB XAN flow regulating valve (16). Repeat this step as required for all FCCB XAN flow regulating valves
(16).
3.
Remove caps/plugs and aline and install four FCCB XAN flow regulating valves (16) into suspension manifold (2).
4.
Apply petroleum jelly to preformed packings (10, 13, and 14) and backup rings (11, 12, and 15).
5.
Install backup ring (15), preformed packings (14 and 13), backup rings (12 and 11), and preformed packing (10)
onto CBCA LAN cartridge valve (9).
6.
Remove caps/plugs and aline and install CBCA LAN cartridge valve (9) into suspension manifold (2).
7.
Apply petroleum jelly to preformed packings (3, 6, and 7) and backup rings (4, 5, and 8).
8.
Install backup ring (8), preformed packings (7 and 6), backup rings (5 and 4), and preformed packing (3) onto
LBCG LCN cartridge valve (1). Repeat this step as required for all LBCG LCN cartridge valves (1).
9.
Remove caps/plugs and aline and install five LBCG LCN cartridge valves (1) into suspension manifold (2).
INSTALLATION
1.
Apply petroleum jelly to 20 preformed packings (30). Install 17 preformed packings (30) onto 17 straight pipe-to-
tube adapters (9). Install three preformed packings (30) onto three tube fitting plugs (29).
4-392