TM 9-2330-384-14&P
4-20. STOP/TAILLIGHT MAINTENANCE (Con"t).
c. INSTALLATION
WARNING
When performing electrical maintenance, ALWAYS disconnect inter-
vehicular electrical cable from semitrailer. Failure to follow this warning
may create a spark and explosion, resulting in serious injury or death to
personnel.
NOTE
Ensure that all wire connections are made to clean, uncorroded sur-
faces. Coat all wire connections with corrosion preventive compound
before they are made.
Curbside stop/taillight has two brown wires (2) at connector (11).
(1)
Connect brown wire (2) from stop/taillight (4) to brown wire inside light box (1). Crimp new
connector (11).
(2)
Connect red wire (10) from stop/taillight (4) to red wire inside light box (1). Crimp new con-
nector (12).
(3)
If removed, install new gasket (3). Install stop/taillight (4) to light box (1) with four screws (5).
FOLLOW-ON TASKS:
l
Check operation of light (see TM 9-2320-273-10 or TM 9-2320-283-10).
l
4-51