Custom Search
|
|
|
||
TM 9-2330-394-13&P
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued
0036 00
ELECTRICAL SYSTEM - Continued
Table 1. Electrical System Troubleshooting Procedures - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
9.
RIGHT BLACKOUT
7.
If 18-26 vdc is not present,
STOPLIGHT DOES NOT
replace intervehicular cable.
ILLUMINATE - CONTINUED
6.
Check to see if continuity is
1.
Open voltage converter box
present across circuit breaker
cover (WP 0053 00).
CB2.
2.
Set digital multimeter to
ohms.
3.
Connect positive (+) probe
of digital multimeter to one
terminal of circuit breaker
CB2.
4.
Connect negative (-) probe
of digital multimeter to other
terminal of circuit breaker
CB2.
5.
If continuity is not present,
replace circuit breaker CB2