Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Custom Search
 
  
 
TM 9-2330-394-13&P
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued
0036 00
ELECTRICAL SYSTEM - Continued
Table 1. Electrical System Troubleshooting Procedures - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
9.
RIGHT BLACKOUT
7.
If 18-26 vdc is not present,
STOPLIGHT DOES NOT
replace intervehicular cable.
ILLUMINATE - CONTINUED
6.
Check to see if continuity is
1.
Open voltage converter box
present across circuit breaker
CB2.
2.
Set digital multimeter to
ohms.
3.
Connect positive (+) probe
of digital multimeter to one
terminal of circuit breaker
CB2.
4.
Connect negative (-) probe
of digital multimeter to other
terminal of circuit breaker
CB2.
5.
If continuity is not present,
replace circuit breaker CB2
0036 00-63


 