Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Custom Search
 
  
 
TM 9-2330-394-13&P
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued
0036 00
ELECTRICAL SYSTEM - Continued
Table 1. Electrical System Troubleshooting Procedures - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
11. LEFT STOPLIGHT DOES NOT
1.
Check to see if continuity is
1.
Loosen six screws on cover.
ILLUMINATE
present through lamp.
2.
Remove cover and
preformed packing from
housing. Discard preformed
packing.
3.
Remove lamp from socket.
4.
Set digital multimeter to
ohms.
5.
Connect positive (+) probe
of digital multimeter to
center of socket side of bulb.
6.
Connect negative (-) probe
of digital multimeter to side
of socket side of bulb and
note reading on digital
multimeter.
7.
If continuity is not present,
replace lamp (WP 0049 00).
8.
Install lamp in socket.
9.
Install preformed packing
and cover on housing with
six screws.
0036 00-72


 