Table 1. Electrical System Troubleshooting Procedures - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
11. LEFT STOPLIGHT DOES NOT
3.
Check to see if continuity is
1.
Open voltage converter box
ILLUMINATE - CONTINUED
present between terminal lug
TL253 and connector J263.
2.
Set digital multimeter to
ohms.
3.
Connect positive (+) probe
of digital multimeter to
terminal lug TL253.
4.
Connect negative (-) probe
of digital multimeter to
connector J263 and note
reading on digital
multimeter.
5.
If continuity is not present,
repair wire (WP 0043 00) or
replace electrical cable
assembly (WP 0051 00).
6.
Connect connector J263 to
left stoplight connector.
0036 00-74


 