TM 9-2350-222-10-3
MAINTAIN MAIN GUN (MAINTAIN BREECHBLOCK ASSEMBLY) - Continued
11. Check that obturator
seat (AM) rests on buffers
(AQ) and that buffers
go down when you
press obturator seat.
If not, disassemble
to follow instructions
carefully.
12. Position connector
rod (AC) and housing
and contact assembly
(AB) on breechblock.
13. Install two screws
(AA) to attach housing
and contact assembly
(AB) to breechblock.
Using hex key (B),
tighten screws until snug.
Change 3