TM 9-2350-230-12
Malfunction
Probable cause
Corrective action
BILGE PUMP SYSTEM
67. Front bilge pump does
a. Loose electrical connection
a. Inspect and tighten con-
not operate when
nections as required.
switch and indicator
b. If circuit breaker does not
light is on
b. Open or defective circuit
breaker
reset in three minutes,
d. Defective bilge pump
a. Turn master switch on.
68. Front bilge pump does
a. Master switch off
not operate when
b. Inspect and tighten or replace
switch is on, indi-
b. Loose electrical connections,
cator light off
defective switch or circuit
components as necessary.
breaker.
c. Defective switch
69. Both rear bilge pumps
a. Loose electrical connections.
a. Inspect and tighten connec-
do not operate when
tions as required.
switch and indicator
light is on
c. Circuit breakers open or
c. If circuit breakers do not
defective
reset in three minutes,
a. Turn on master switch.
70. Both rear bilge pumps
a. Master switch off
do not operate when
b. Inspect and tighten electri-
switch is on, indi-
b. Loose electrical connections.
cator light off
cal connections, as
required.
a. Defective switch
71. Only one rear bilge
a. Loose electrical connections.
a. Inspect and tighten connec-
pump operates
tions to inoperative pump
and associated circuit
breaker.
b. If circuit breaker does not
b. Circuit breaker open or
defective
reset in three minutes,
c. Replace bilge pump (figs. 9-
c. Defective bilge pump
129, 130).
8-29