C 14, TM 9-2350-230-12
Table 10-3. Electric Drive Control System Test Procedure
--Continued
METER ADJUSTMENT PROCEDURE
Electronic Test Set (4933-00-909-9356)
Turn on turret power switch; ready light illuminates after 18 to 22 seconds. With multimeter, check +15 volts at pin "D"
and -15 volts at pin WE" of amplifier integrator test set receptacle (J2).
1. If voltage at pin "D" is from +14 to +16 volts and voltage at pin "E" is from -14 to -16 volts, turn off turret power,
reconnect test set harness to receptacle and turn on turret power. Wait until ready light illuminates.
2. Place test set selector to TP-6 and move red arm on right of test set meter to the left until Right/Up lamp
illuminates.
3. Place test set selector to TP-7 and move red arm on left of test set meter to the right until Left/Down lamp
illuminates.
10-8.13