6-7. GENERATOR FIELD SAFETY SWITCH DEFECTIVE
General Information
field safety switch (on fuel filter).
Limitations
q Continued
usage of a bypassed switch will cause eventual damage to the fan tower
pulley and shaft.
Personnel/Time Required
q1
soldier
q5
minutes
Materials/Tools:
q Metal pin
q Bare jumper
wire
q Knife
Other Options:
q The
wires may be stripped
and twisted together, if
necessary.
Procedural Steps:
1. By-pass the field safety
switch (fuel pressure switch),
located on the secondary
fuel filter.
2. Disconnect the cable
lead.
3. Connect circuits 1A and lB
of the cable with a jumper wire.
This allows current to energize
4. Record the BDAR action taken.
When the mission is completed, as
soon as practicable, repair the
vehicle using standard maintenance
procedures.