TM 9-2350-277-10
PREVENTIVE MAINTENANCE CHECKS AND SERVICES -- Continued
0090 00
Table 6. Preventive Maintenance Checks and Services for Model M113A3 FOV, Weekly
ITEM
INTERVAL
MAN-
ITEM TO BE
CREWMEMBER
EQUIPMENT
NO.
HOUR
CHECKED OR
PROCEDURE
NOT READY/
SERVICED
AVAILABLE
IF:
81
Weekly
Power Plant
Access Door and
Trim Vane
NOTE
Do PREVENTIVE MAINTENANCE
steps each week or before operation if
you are operating the carrier for the
first time.
Carrier commander will direct
and assist in weekly, monthly, and
semi-annual PMCS.
a.
Check that access door, door seal, and trim
vane are serviceable.
b.
cracks, and poor seating.
c.
Check access door for watertight fit. Make
Access door
sure door locks.
will not close
and lock.
d.
Check trim vane for cracks, warps, and
separation of plywood.
e.
Operate trim vane control handle. Make
sure adjustment is right in both the stowed
and open position.
Change 4