TM 9-2590-209-14&P
NOTE
Control lever must remain in H (hold) position during this
process.
______________________________________________
Section XV. INSTALLATION OF RESERVOIR VENT LINE
e. Install assembled components to bracket
9-39. General. This section provides instructions for
on reservoir so that nipple on filter projects through
the installation of the reservoir vent line.
slotted hole in bracket; secure with nut MS35691-45. Do
not tighten.
NOTE
f.
Align slotted holes in bracket 12257379 with
Only vehicles having a top loading air
threaded holes in reservoir bracket, and install two
cleaner can accept the M9 bulldozer kit.
The air breather parts (reservoir vent
washers MS27183-10.
line) installation is not compatible with
the side loading air cleaner.
g. Remove plug in center of reservoir cover,
and discard.
9-40.
h. Apply sealing compound per specification
a. Apply sealing compound per specification
reservoir cover.
and install elbow in air cleaner box.
I.
Apply sealing compound per specification
b. Install hose assembly MS28762-60740 to
elbow, and secure to side of air cleaner box with four
install to elbow.
clamps MS21333-126 using existing screws.
j.
Install tube assembly 12257381 between
c. Place clamp MS21333-126 on hose
elbow and filter. Start tube nuts on both ends; then align
assembly, and install on welded plate with screw
tube and filter so that tube assembly rests on reservoir
MS90728-57, lockwasher MS35338-46, and washer
cover. Tighten all nuts and screws on tube and filter.
MS27183-14. Do not tighten.
k. Install hose assembly MS28762-60740 to
d. Install nipple MS51812-25 with packing
other end of filter, and tighten hose and clamps
MS828778-6 on each end of filter AN6240-1. Install filter
previously left loose.
to bracket 12257379 with nut MS35691-45 so that arrow
on filter points toward bracket. Do not tighten.
___________________________________________
9-34