TM 9-3405-215-14&P
NAME
NUMBER
1434
PROJECT
ENGINEERING ADJUSTMENT SUMMARY
120789-2
11
11
SHEET
OF
MODEL DBW-15
FIG. 6
FINAL JAW ALIGNMENT
A weld must be made in 1" x .035 ga. Imperial band in order to check the final alignment. The
finished weld must be within 4% of the band gage. The tooth edge of the band must be straight
within .004" in 4" measured 2" on either side of the weld. To make this weld:
1. Set the jaw upset force knob to its maximum wide position.
2. Set the initial jaw gap by adjusting the position of the weld lever. It must be set to the line indicating
the widest width.
3. Make the final jaw alignment adjustment as required to result in the tolerances listed.
Prepared by: Roger Harris
Approved:
Date: 7-31-69
153 (154 blank)