TM 9-4110-246-14
TO 40R7-5-10-1
INSPECTION
1. Inspect gasket panels or removed panel assembly and/or the immediately connecting panel assembly(s) as
applicable.
2. Check gasket panels for deterioration, cracks, tears, breaks, missing sections, or other damage. Replace as
3-18.
REMOVE/INSTALL GASKET PANEL.
TOOLS:
Staple Remover
Staple Gun
Tape Measure
SUPPLIES:
Gasket Material
Staples
NOTE
PRELIMINARY PROCEDURE: Inspect gasket panel per para. 3-17.
REMOVAL
1. Note position of gasket panels (1) on panel assembly requiring gasket replacement.
2. With tape measure, note and record length of gasket panel requiring replacement.
3. Strip damaged gasket panels (1) from panel assembly by removing staples with stable remover.
INSTALLATION
1. Cut gasket panels to sufficient lengths as recorded for a continuous run.
2. Install replacement gasket panel on panel assembly using staple gun with staples spaced 1 1/2" (54 mm) apart.
3-21