4-34. DUMMY STOWAGE CONNECTOR AND COVER REPLACEMENT.
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Materials/Parts
General Safety Instructions
Lock Washers (2)
WARNING
Self Locking Nuts (4)
High voltage and exposed rotating parts are
used in the refrigeration unit. Personal injury
Equipment Conditions
can result if power is connected
disconnected.
Control box cover door raised and latched.
a. Removal.
(1)
Be sure power has been disconnected at the source and remove two bolts (1) and lock washers (2) Open
control panel (3). Discard lock washers
(2)
Remove four self locking nuts (4), bolts (5), cover (6), and dummy stowage connector (7) Discard self
locking nuts
Figure 4-29. Dummy Stowage Connector and Cover