TM 9-4110-254-14
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Equipment Conditions:
General Safety Instructions.
WARNING
disconnected.
High voltage and exposed rotating parts are
used m the refrigeration unit. Personal injury
can result if power is connected
a. Removal.
(1)
Loosen two set screws (1)
(2)
Carefully pull evaporator fan (2) off fan drive shaft (3) and remove.
Figure 4-38. Evaporator Fan
b. Installation
(1)
Install fan (2) on fan drive shaft (3).
(2)
Tighten two set screws (1) against flat surfaces on fan drive shaft.
NOTE
FOLLOW-ON MAINTENANCE
Connect power and put unit back into service.
4-94