TM 9-4110-254-14
5-23.
ACCUMULATOR REPLACEMENT.
This task covers:
a
Removal
b. Installation
INITIAL SETUP
Materials/Parts.
Equipment Conditions:
Self Locking Nuts (2)
Insulation Tape
Left side door open.
a. Removal.
(1) Remove insulation (1) as necessary.
(2) De-braze two fittings (2) from accumulator (3) (para 5-9).
(3) Remove self locking nut (4), flat washer (5), flat washer (6), and bolt (7). Discard self locking nut.
NOTE
Note flow direction prior to removal.
(4) Remove self locking nut (8), flat washer (9) and accumulator (3). Discard self locking nut.
b. Installation
NOTE
Be sure to observe flow direction noted during removal.
(1) Install accumulator (3), flat washer (9), and new self locking nut (8).
(2) Install flat washer (7), bolt (6), flat washer (5), and new self locking nut (4).
(3) Braze two fittings (2) onto accumulator (3) (para 5-9).
(4) Install insulation (1) and secure with insulation tape as necessary
5-47