4-17. BARREL BOLT REPLACEMENT.
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Materials/Parts:
General Safety Instructions:
Lock Washers (6) (Each Barrel Bolt Assembly
WARNING
Equipment Conditions:
Exposed rotating parts are used in the
refrigeration unit. Personal injury can result if
battery is connected.
a. Removal.
(1) Remove four bolts (1), lock washers (2), and barrel bolt (3). Discard lock washers.
(2) Remove two bolts (4), lock washers (5), and barrel bolt clip (6). Discard lock washers.
b. Installation.
(1) Install barrel bolt clip (6), two new lock washers (5), and bolts (4).
(2) Install barrel bolt (3), four new lock washers (2), and bolts (1).
Figure 4-11. Barrel Bolt
NOTE
FOLLOW-ON MAINTENANCE:
Connect battery (para. 4-35) and put unit back into service.
4-43