TM 9-4110-256-14
c.
Installation.
(1) Install contactor (5), four flat washers (9), new lock washers (8), and bolts (7).
(2) Using tags and wiring diagram (fig. 1-4), install wire leads (6). Remove tags.
(3) Close control box cover (3). Install two new lock washers (2) and bolts (1).
Figure 4-20. Contactor
NOTE
FOLLOW-ON MAINTENANCE:
Close control panel cover.
Connect power and put unit back into service.