TM 9-4110-256-14
4-29. REPEAT CYCLE TIMER TM1 TESTING AND REPLACEMENT. - Continued
NOTE
Terminal hardware is supplied with repeat cycle timer.
(4)
Tag wire lead terminals (7) and remove seven screws (8), lock washers (9), and wire lead terminals.
(5)
Remove two self locking nuts (10), screws (11), and relay mounting socket (6). Discard self locking nuts.
c.
Installation.
(1)
Install relay mounting socket (6), two screws (11), and new self locking nuts (10).
(2)
Using tags and wiring diagram (fig. 1-4), install wire lead terminals (7), seven lock washers (9), and
screws (8). Remove tags.
(3)
Push repeat cycle timer (5) into relay mount socket (6) and install new tie down strap (4).
(4)
(5)
Close control box cover (3) and install two new lock washers (2) and bolts (1).
NOTE
FOLLOW-ON MAINTENANCE:
Close control panel cover.
Connect power and put unit back into service.
4-60