TM 9-4110-256-14
(11) Install cover (5) and screw (4).
(12) Close control box cover (3) and install two new lock washers (2) and bolts (1).
b. Removal.
(1)
Be sure power has been disconnected at the source and remove two bolts (1) and lock washers (2). Open
control box cover (3). Discard lock washers.
(2)
Remove screw (4) and cover (5).
(3)
Remove two self locking nuts (6), bolts (7), and sensing bulb bracket (8). Discard self locking nuts.
(4)
Remove self locking nut (9), bolt (10), and sensing bulb bracket (8). Discard self locking nut.
(5)
Remove clamp (11).
(6)
Tag wire leads (15) then remove two screws (16) and wire leads.
(7)
Pull wire leads (15) from remote bulb thermostat (13) and remove grommet (17).
(8)
Remove tie down straps (18).
(9)
Remove four self locking nuts (19), bolts (20), and flat washers (21). Discard self locking nuts.
(10) Remove remote bulb thermostat (13) and any grommets (22) and (23) necessary to remove sensing bulb
(12).
(11) If temperature control switch bracket (24) is damaged, remove two self locking nuts (25), flat washers
(26), screws (27), and bracket. Discard self locking nuts.
(12) Remove any silicone RTV remaining in evaporator frame grommets (22).
c.
Installation.
(1)
If removed, install temperature control bracket (24), two screws (27), flat washers (26), and new self
locking nuts (25).
(2)
Install remote bulb thermostat (13) routing sensing bulb (12) through grommets (22) and (23). Install any
grommets removed.
(3)
Install remote bulb thermostat (13), four flat washers (21), bolts (20), and new self locking nuts (19).
(4)
Install tie down straps (18) as necessary.
(5)
Install grommet (17) and push wire leads (15) into remote bulb thermostat (13).
(6)
Using tags and wiring diagram (fig. 1-4), install wire leads (15) and two screws (16). Remove tags.
(7)
Slip clamp (11) over sensing bulb (12).
(8)
Install clamps (11) and (14), bolt (10), and new self locking nut (9).
(9)
Install sensing bulb bracket (8), two bolts (7), and new self locking nuts (6).
4-63