TM 9-4110-256-14
b. Removal.
(1)
Be sure power has been disconnected at the source and remove two self locking nuts (1), bolts (2), and
sensing bulb bracket (3). Discard self locking nuts.
(2)
Remove self locking nut (4), bolt (5), and sensing bulb clamp (6). Discard self locking nut.
(3)
Remove clamp (6) from sensing bulb (7).
(4)
Remove tie down straps (10).
(5)
Remove three self locking nuts (11) and bolts (12). Discard self locking nuts.
(6)
Remove thermometer (8) and any grommets (13) necessary to remove sensing bulb (7).
(7)
Remove any silicone RTV remaining in evaporator frame grommets (13).
c.
Installation.
(1)
Install thermometer (8) routing sensing bulb (7) through grommets (13). Install any grommets removed.
(2)
Install thermometer (8), three bolts (12), and new self locking nuts (11).
(3)
Install tie down straps (10) as necessary.
(4)
Slip clamp (6) over sensing bulb (7).
(5)
Install clamps (6) and (9), bolt (5), and new self locking nut (4).
(6)
Install sensing bulb bracket (3), two bolts (2), and new self locking nuts (1).
(7)
Apply silicone RTV into evaporator frame grommets (13) to seal evaporator enclosure.
NOTE
FOLLOW-ON MAINTENANCE:
Close control panel cover.
Connect power and put unit back into service