TM 9-4110-256-14
4-40.
PULLEY REPLACEMENT.
This task covers: a. Removal
b. Installation
INITIAL SETUP
General Safety Instructions:
Equipment Conditions:
disconnected.
WARNING
High voltage and exposed rotating
parts are used in the refrigeration unit.
Personal injury can result if power is
connected.
a. Removal. Loosen set screw (1) and remove pulley (2) from AC motor (3) shaft being careful key (4).
b. Installation. Install key (4) then aline pulley (2) with key and slide :to AC motor (3) shaft. Tighten set screw (1).
Figure 4-35. Pulley
NOTE
FOLLOW-ON MAINTENANCE:
Connect power and put unit back into service.
4-85