1.7 REPORTING EQUIPMENT IMPROVEMENT RECOMMENDATIONS (EIR).
If your refrigeration unit needs improvement, let us know. Send us an EIR. You, the user, are the only one who can tell
us what you don't like about your equipment. Let us know why you don't like the design or performance. Put it on an SF
368 (Product Quality Deficiency Report). Mail it to:
Commander
US. Army Aviation and Troop Command
ATTN: AMSAT-I-MDO
4300 Goodfellow Blvd.
St. Louis, MO 63120-1798
1.8 WARRANTY INFORMATION.
Refer to TB 9-4110-25823 for specific warranty information.
1.9 CORROSION PREVENTION AND CONTROL..
1.9.1 Corrosion Prevention and Control (CPC) of Army material is a continuing concern It is important that any corrosion
problems with this item be reported so that the problem can be corrected and improvements can be made to prevent the
problem in future items.
1.9.2 While corrosion is typically associated with rusting of metals, it can also include deterioration of other materials,
such as rubber and plastic. Unusual cracking, softening, swelling, or breaking of these materials may be corrosion
problem.
1.9.3 If a corrosion problem is identified, it can be reported using Standard For 368, Product Quality Deficiency Report.
Use of keywords such as "corrosion," rust," "deterioration," or cracking" will ensure that the information is identified as a
CPC problem.
1.9.4 The form should be submitted to the address specified in DA Pam 738-750.
SECTION II EQUIPMENT DESCRIPTION
1.10 EQUIPMENT CHARACTERISTICS. CAPABILITIES AND FEATURES.
1.10.1 Characteristics. The Keco Model F900RE, is a self-contained, refrigeration/heating unit for military van
containers. The unit is designed to allow for starting and operating on a 10 KW, 60 hertz generator set.
1.10.2 Capabilities. The unit is capable of starting and operating in ambient temperature from 0F to 125F.
1.10.3 Features. The unit is designed to use R134a refrigerant The portion of condensing unit exposed to the weather
can operate in rainfall of 3 inches per hour minimum without functional damage or impairment of operation. It can
automatically control both cooling and heating the container and automatically switching from cooling to heating and
heating to cooling. The unit can operate on a 50 Hz power source with a voltage range of 180 to 230 volts and on a 60
Hz power source with a voltage range of 200 to 250 volts.