TM 9-4120-370-14
TO 35E9-229-1
5-5.
Preliminary procedure:
See paragraph 4-64 for testing (installed), removal, and installation.
Authorized repairs. Direct support maintenance repair of the condenser fan motor is limited to the repl a c e ment
a.
b.
Disassembly. Disassemble motor only as necessary to do required repair. (See Figure 52.)
(1) To replace connector (J2):
(a) Using screwdriver, remove four screws from terminal box cover.
(b) Remove cover.
(c) Remove four screws from connector (J2).
(d) Pull connector away from terminal box as far as wires will allow.
Remove old connector.
(f)
(9) See wiring diagram and tags and solder leads to new connector.
(h) Remove tags.
(i)
Using screwdriver, secure connector to terminal box with four screws.
Using screwdriver, secure terminal box cover to box with four screws.
(j)
(a) Match-mark motor frame and both end brackets to ease reassembly.
(b) Using wrench, remove four nuts from one end of motor studs. Retain motor stud with vice grips or
pliers.