TM 9-4120-378-14
4.25 JUNCTION BOX. - continued
Remarks
Action
Location/Item
Inspection
. Continued
tacts 2 to 3.
Apply 24 5 volts DC power across terminals 1
and 5. Voltage indicated should be 24 5 volts
DC. After approximately a 30-second time delay,
voltages at terminals 1 and 3 should be 24 volts
5 volts DC. If not, replace.
Replace if fails test.
See Fig FO-3 and Fig FO-4.
Tag and disconnect wire leads to terminals 1 and 2.
Time Delay
Use a continuity tester or a multimeter set to the
Model
lowest ohms scale to check continuity between
F9000H1S
indicated.
Apply 24 5 volts dc power across terminals 1
and 2. Voltage indicated should be 24 5 volts
dc. After approximately a 30 second time delay,
voltages at terminals 1 & 2 should be 24 5 volts
dc. If-not, replace.
Replace if fails test.
4-57