ARMY TM 9-4120-380-14
NAVY EE-000-BA-MMA-010/7053-AC
AIR FORCE TO 35E9-136-21
4.50
CONDENSER FAN AND HOUSING ASSEMBLY. Continued.
INSTALLATION
NOTE
When replacement of the fan housing assembly is necessary, perform the following:
Enlarge the five flange mounting holes from 9/64 inches to 13/64 inches. Install rivnuts
and pant the fan housing assembly. When replacement of the flange is necessary, paint
the replacement flange.
a. Position fan housing assembly (1) to motor (11) and secure with four bolts (4), lockwashers (3), and flat washers
(2).
b. Position fan (5) onto motor (11) shaft and secure with set screw (10).
c.
Position flange (9) to fan housing assembly (1) and secure with five screws (6), lockwashers (7), and flat washers
(8).
FOLLOW ON PROCEDURES
a.
b. Connect air conditioner input power at source.
4-108