ARMY TM 9-4120-380-14
NAVY EE-000-BA-MMA-010 7053-AC
AIR FORCE TO 35E9-136-21
5.33. DAMPER ACTUATOR. - Continued
TESTING
-
continued
i.
Remove service manifold from nitrogen cylinder.
j.
Remove service manifold from actuator.
k.
Hand tighten flarenut (12) to actuator (11).
l.
m.
Let gas escape from flarenut for 1 to 3 seconds and tighten flarenut (12).
REMOVAL
a.
b.
Slowly loosen flarenut (12) on actuator to release gas, then remove flarenut.
c.
Remove two locknuts (1) and flat washers (2) securing actuator to bracket (3).
d.
Remove two screws (9), lockwashers (10), and bracket (3).
e.
Remove locknut (4), flat washer (5), and actuator rod and swivel (6).
f.
Remove actuator (11).
g.
Remove two rivets (8) and actuator linkage bracket (7) from actuator (11).
INSTALLATION
a.
Install actuator linkage bracket (7) to actuator (11) with two rivets (8).
b.
Install actuator swivel and control rod (6) with flat washer (5) and locknut (4).
c.
Install actuator to bracket with two flat washers (2) and locknuts (1).
d.
Install bracket (3) with two screws (9) and lockwashers (10).
e.
Hand tighten flarenut (12) to actuator (11).
f.
g.
Let gas escape from flarenut for 1 to 3 seconds and tighten flarenut (12).
h.
FOLLOW ON PROCEDURES
a.
Install condenser fan section panel (paragraph 4.23) b. Connect air conditioner input power at source.
5-80