TM 9-4120-399-14
5-32. TUBING AND FITTINGS.
This Task Covers:
b. Installation
a. Removal
Initial Setup:
Tools Required
Tool kit, Refrigeration
Material's Required
None
Equipment Condition
Air conditioner shut down and cool.
Covers and panels removed as necessary to have access to repair area (See para.
NOTE
The refrigeration system contains a number of pieces of copper
tubing in a variety of material grades, sizes, lengths, and shapes, and
a number of elbows, tees, and adapters in several sizes. Observe the
following when replacing any piece of tubing or fitting in the
system.
a. Removal.
NOTE
Any debrazing near the fusible will require the fusible to be removed
before debrazing.
After completion of the debrazing process, remove the part.
b. Installation.
(1) Install replacement part onto tube ends.
NOTE
Any debrazing near the fusible will require the fusible to be removed
before brazing.