TM9-4120-400-14
1.8. LOCATION AND DESCRIPTION OF MAJOR COMPONENTS. - contined
37 INPUT POWER RECEPTACLE (ALTERNATE LOCATION). The main power cable may be connected
here. See item 10 for primary location. See installation instructions for switch-over instructions if this power
receptacle is used.
38 REFRIGERANT SIGHT GLASS. Visually indicates the condition of the refrigerant flowing in the refrigerant
lines during cooling cycles when operating in the COOL mode.
39 ACTUATING CYLINDER. This hydraulic cylinder operates discharge louver assembly. It will start to open
the louver assembly at 150 to 180 psig (10.55 to 12.66 kg/cm2) and fully open louver assembly at 220 to 260 psig
(15.74 to 18.28 kg/cm2) compressor discharge pressure to allow unit operation when outside temperature is low.
1-9. DIFFERENCES BETWEEN
MODELS
The basic difference between the Model F9000H-3SA and the Model F9000H-1SA air conditioners is the source
of power. The F9000H-3SA uses 208 volt, 3 phase, 50/60 hertz power and the F9000H-1SA uses 115 volt,
single phase, 50/60 hertz power. The operator needs to ensure that the correct power cable and correct power
source is used for each of the two types of unit.
F9000H-1S
A
F9000H-3S
A
AMBlENT OPERATING TEMPERATURE RANGE
-50F (-45C)
+120F (+49C)
PERFORMANCE AT 50 HERTZ
8,333 BTU/HR
8,333 BTU/HR
COOLING CAPAClTY
7,000 BTU/HR
7,000 BTU/HR
PERFORMANCE AT 60 HERTZ
10,000 BTU/HR
10,000 BTU/HR
COOLING CAPACITY
7,000 BTU/HR
7,000 BTU/HR
POWER REQUIRED
115
VOLTAGE
208
1
PHASE
3
50/60
HERTZ
50/60
20
AMPERAGE
10
4
KILOWATTS
4
DIMENSIONS
24.0 inch (60.96 cm)
WIDTH
24,0 inch (60.96 cm)
26.5 inch (67.31 cm)
DEPTH
26.5 inch (67.31 cm)
16.0 inch (40.64 cm)
16.0 inch (40.64 cm)
HEIGHT
185 pounds (83.9 kg)
WEIGHT
185 pounds (83.9 kg)
REFRIGERANT
TYPE
R-22
R-22
2.2 pounds (1.0 kg)
2.2 pounds (1.0 kg)
CHARGE
1 -7