TM9-4120-400-14
4-11.
TOP PANELS. - continued
NOTE
Top rear panel (4) and access panel (13) can be removed independently. Top center
panel (9) must be removed last.
REMOVAL
1.
Remove eight screws (1) and top front panel (2).
2.
Remove seven screws (3) and top rear panel (4).
3.
On single phase unit only remove run capacitors C2 and C3 (5 and 6). (See para 4-36.)
4.
On single phase unit only remove start capacitor C5 (7). (See para 4-37.)
Remove six screws (8) and top center panel (9).
5.
6.
Carefully raise top center panel (9) and remove two screws (10) and heater cutout switch bracket (11).
7.
Remove four screws(12) and access panel (13).
Dry cleaning solvent used to clean parts is potentially dangerous to personnel and
property. Do not use near open flame or excessive heat. Use in well ventilated area.
CLEANING
Clean the panels with a rag dampened with a detergent solution or dry cleaning solvent. Use a soft brush if
necessary to dislodge caked on dirt. Dry the items thoroughly.
INSTALLATION
1.
Secure access panel (13) to top rear panel (4) with four screws 12).
2.
Secure heater cutout switch bracket (11) to top center panel (9) with two screws (10).
3.
Install top center panel (9) with six screws (8).
4.
On single phase unit only install start capacitor C5 (7). (See para4-37.)
5.
On single phase unit only install run capacitors C2 and C3 (5 and 6). (See para 4-36.)
Install top rear panel (4) with seven screws (3).
6.
7.
Install top front panel (2) with eight screws (1).
NOTE
FOLLOW-ON MAINTENANCE:
Connect power at power source.
4-40