TM9-4120-400-14
5-8.
Figure 5-7. Condenser Fan Motor Assembly, IMC Magnetics Corp., Single Phase Motor, Model BC5320
(1) Match mark stator (3) and end cap (4) to ease reassembly.
(2) Remove four screws (5) and lock washers (6) from end cap.
(3) Carefully separate end cap (4) from stator (3). Using a brass or plastic bar and hammer tap opposite
sides, top, and bottom in alternating sequence to break end cap loose.
Remove end cap carefully to avoid damaging wires. Wires maybe left in place if care is
taken to avoid damaging them.
NOTE
Be sure load spring and spacer washers are not lost during motor disassembly. Note their
position for use in reassembly.
(4) Remove end cap (4).
(5) Carefully slide rotor (9) out of stator housing (3).
(6) Press out or carefully drive bearings (10) out of end cap (4) and stator housing (3). Retain load spring
(7) and spacer washers (8) for use at reassembly if not damaged.
(7) Examine rotor (9), stator (3), and shafts for nicks, gouges, deformations, and evidence of overheating.
(8) Dress high metal defects in shafts with a fine file or stone. If damage exceeds repairable limits, replace
motor.
5-21