TM 9-4120-403-14
Repair
(1)
Remove as much old gasket or insulation material as possible, by pulling or scraping away from the metal
surface.
(2)
Soften and remove old adhesive and gasket or insulation residue, using toluene and a stiff brush.
(3)
Cut replacement gasket or insulation to size per dimensions in Appendix F.
(4)
Be sure that the surface to which the gasket or insulation is to be applied is clean and free of old adhesive
material.
(5) Coat the mating surfaces of the metal and the gasket or insulation with adhesive. Let both surfaces air dry
until the adhesive is tacky, but will not stick to fingers.
(6)
Starting with an end, carefully attach the gasket or insulation to the metal. Press into firm contact all over.
Installation
(1)
Set the bottom of the panel in position so that the flange is inside the lip on the cabinet base.
(2)
Push the top of the panel back into position.
(3)
Secure panel to casing with two captive panel fastener screws.
4-37