TM 9-4120-403-14
Removal
Lift mist eliminator straight up and out of brackets.
Cleaning
(1) Wash in mild detergent and water solution.
(2) Rinse thoroughly in clear water.
(3) Shake out excess water prior to installation.
Inspection
(1) Check for punctures, cuts, and other visible damage.
(2) Check for packed or mashed areas that would block air flow.
(3) Replace if defective.
Installation
Slide mist eliminator straight down into brackets.
Follow-on procedure:
4-51