TM 9-4120-403-14
Removal
(1)
Remove four screws and lockwashers securing circuit breaker and circuit breaker cover.
(2)
Tap out shaft that holds reset toggles together and disconnect reset actuator arm.
(3)
Tag and remove wires.
(4)
Remove circuit breaker.
NOTE
See paragraph 4-34 for repairs on circuit breaker push-pull reset parts.
Installation
(1)
Place actuator arm into position and insert toggle shaft.
(2)
Install circuit breaker and circuit breaker cover with four screws and lockwashers.
(3)
Using tags and wiring diagram (fig. 4-43) connect leads.
(4)
Install junction box cover with four panel fastener screws.
Follow-on procedure: Install junction box. (See para 4-32.)
4-81