TM 9-4120-404-14
3-35. LOUVER ACTUATOR CABLES.
This Task Covers:
a. Removal
b. Repair
c. Installation
d. Adjustment
Initial Setup:
Tools Required
Tool Kit, Service, Refrigeration, Unit (Item 1, Appendix B)
Material/Parts Required
None
Equipment Condition
Air conditioner shut down and cool.
(1) Remove cable ties from louver cables.
(2) Remove screw (1) and cable clip (2).
(3) Remove two mechanical posts (3) from ends of louver actuator cables (4) and (5).
(4) Remove two screws (6) and two nuts (7) attaching louver actuator cables (4) and (5) to louver assemblies.
(5) Compress clamps (8) on louver actuator cables (4) and (5) and pull cables through control bracket (9).
(6) Compress clamps (10) on louver actuator cables (4) and (5) and pull cables through angle (11) on
(7) Remove all cable ties (14) used to hold louver actuator cables (4) and (5) in place and remove both cables.
(8) Remove four screws (15), four lock washers (16), bracket (17), and control bracket (9).
b. Repair.
Repair of louver actuator cables is limited to replacement of defective or damaged components.
3-82