TM
9-4120-407-14
Table 3-2. Unit Preventive Maintenance Checks and Services for Model F36T-MPI - Cont
Location
Procedures
Item To
Item
Interval
Not Fully Mission Capable
Check/Service
if:
No
Safety Control Box
27
Annually
Check circuit breaker for any
Circuit breaker is damaged.
Circuit Breaker -
visible damage such as
Cont
broken or stripped terminal
screw posts, cracked or
broken case, or burns. Test or
replace as necessary per
Check that circuit breaker is
securely mounted. If loose,
secure it.
Assemble and install safety
control box assembly. See
Annually
Condenser Coil
28
visible damage such as
kinked, crushed, or punctured
tubes, crushed or missing fins,
and any evidence of leaking.
If tubes are damaged or
there is any evidence of
leaking, notify Direct
Support Maintenance. If fins
are crushed but repairable,
carefully straighten them
using a fin comb
3-42