TM 9-4120-408-14
4-27. CONTROL MODULE HOUSING MAINTENANCE. (Continued)
INSERT SUBTITLE HERE!
This task covers:
Remove
Install
INITIAL SETUP:
Tools
Equipment Conditions
Tool Kit, Service Refrigeration Unit,
General Safety Instructions
Material/Parts
Do not work on equipment without following standard
Refer to TM 9-4120-408-24P for part numbers of items
shop safety procedures.
to be replaced.
Figure 4-22. Return Air Filter Mounting Bracket Replacement.
a. Remove.
Remove two screws (Figure 4-22, 1)
and return air filter mounting bracket (2) -
b. Install. .
(1) Position return air filter mounting bracket (2) on evaporator assembly (3) and secure with two screws (1).
(2) Follow on maintenance: refer to paragraph 3-S and install return air filter.
4-47