TM 9-4120-408-14
This task covers: Inspect
Repair
Test
Install
Remove
INITIAL SETUP
Tools
Tool Kit, Service Refrigeration Unit,
Materials/Parts (Continued)
Section III, Item 2
Section III, Item 4
Item 12 (A106J1
Connector)
Recovery and Recycling Unit, Refrigerant,
Item 9
Refer to TM 9-4120-408-24P for part
Manifold Gage, Charging and Testing
numbers of items to be replaced.
Equipment Condition
Item 17)
Material/Parts
Power disconnected,
refer
to
applicable
system
technical manual.
General Safety Instructions
Do not work on equipment without following standard
shop safety precautions.
Ensure that power has been disconnected before
performing maintenance on electrical components.
Item 13
WARNING |
Item 16
Do not work on equipment with power
connected.
Electrocution hazard is
present. Failure to obey this warning may
result in death or serious personal injury.
CAUTION
Dehydrator must be replaced every time the air conditioner lines are exposed to the atmosphere. Failure
to obey thin caution may result in equipment damage.
Change 1 5-51