TM 9-4120-408-14
5-22. EVAPORATOR HIRING HARNESS, A106J1,-MAINTENANCE. (Continued)
(3) Remove and discard all tiedown straps securing wiring harness A106J1 (1) to any electrical lead-.
(4) Remove four nuts (6), lock washers (7), flat washers (8), screws (9), connector A106J1 (10) of wiring
harness A106J1 (1), and gasket (11). Discard lock washers (7) and gasket (11).
b. Inspect.
(1) Inspect for loose wires in connector A106J1 (10).
(2) Inspect all wiring harness A106J1 (1) wires for cracked insulation, damaged or missing connectors and
terminals, burns, or fraying.
(3) Inspect all mounting hardware for damage.
(4) Replace all damaged or defective components.
c.
Test.
harness A106J1 (1).
d.
e.
Install.
(1) Install new gasket (11) and connector A106J1 (10) in evaporator housing (12) and secure with four screws
(9), flat washers (8), new lock washers (7), and nut n (6).
(2) Secure wiring harness A106J1 (1) to electrical leads with new tiedown straps located approximately every
three inches.
(3) Install ten cushion clamps (5) on wiring harness A106J1 (1) and secure them to evaporator housing (12)
with ten flat washers (4), new lock washers (3), and nuts (2).
harness A106J1 (1). Remove and discard tags.
(5) Follow on maintenance :
(a)
(b)
(c)
(d)
Refer to applicable system technical manual and connect power.
5-53