TM 9-4120-411-14
(1) Support cover (2) then remove hair pin cotter (5). Remove cover retaining rod (3) from latch hinge doubler
(4) then lower cover retaining rod to storage position being sure end is in compressor brace slot. Carefully
lower cover and secure with two latch hinges (1).
4.3 SERVICE UPON RECEIPT OF MATERIEL.
4.3.1 Checking Equipment.
4.3.1.1 Inspect the equipment for damage done in shipment. Report any damage on SF 364 (Report of Discrepancy).
WARNING
The FDECU cover is heavy. Be sure the cover retaining rod is in place and
properly secured with hair pin cotter. Injury can occur if cover drops.
4.3.1.2 Check equipment against the packing slip to make sure the shipment is complete. Report all discrepancies in
accordance with the instructions of DA PAM 738-750 or DA PAM 738-751 as applicable. Raise and secure cover to
check packed components inside unit. Lower and secure cover after checking. Raise and lower cover per paragraph 4.2.
4.4 INSTALLATION INSTRUCTIONS.
4.4.1 Tools, Test Equipment, and Materials Required for Installation. Only basic hand tools found in general
4.4.2 Place unit in operating position at shelter in accordance with site requirements paragraph 4.1.
WARNING
The FDECU cover is heavy. Be sure the cover retaining rod is in place and
properly secured with hair pin cotter. Injury can occur if cover drops.
4.4.3.1 Raise and secure cover per paragraph 4.2 to access packed components inside unit.
4.4.3.2 Carefully uncoil input power cable assembly (1). Lay cable outside unit and rest in end panel notch (2).
4.4.3.3 Remove two ducts (3).
4-5