TM 9-4910-387-14-1
REPAIR OF PLATE PARTS I
1
PLATE (1).
a. Loosen and back off setscrew (2)
with socket headscrew key.
b. Remove.
2
PLATE (3).
a. Remove three screws (4) and
three washers (5).
b. Remove.
NOTE
Repair is by replacement
of authorized parts (TM 9-
4910-387-24P) as required.
3
PLATE (3).
a.
Position on front of tester.
b.
Install with three washers (5) and
three screws (4).
4
PLATE (1).
a.
Position on shouldered shaft (6)
leaving 1/32-in. (0.079-cm) gap
between plate (3).
b.
Tighten setscrew (2) using a sock-
et headscrew key.
4-37